TECHNICAL SPECIFICATIONS/CERTIFICATIONS MSA
44 ALTAIR PRO - Operating Manual
Sensor SO
2
(Sulfur Dioxide)
Range 0-20.0 ppm
Resolution 0.1 ppm
Sensor NO
2
(Nitrogen Dioxide)
Range 0-20.0 ppm
Resolution 0.1 ppm
Sensor NH
3
(Ammoniac)
Range 0-100 ppm
Resolution 1 ppm
Sensor PH
3
(Phosphine)
Range 0-5.0 ppm
Resolution 0.05 ppm
Sensor HCN (Hydrogen Cyanide)
Range 0-30.0 ppm
Resolution 0.5 ppm
Sensor Cl
2
(Chlorine)
Range 0-20.0 ppm
Resolution 0.1 ppm
Sensor ClO
2
(Chlorine Dioxide)
Range 0-1.00 ppm
Resolution 0.02 ppm
* normal temperature range 0-40 °C
** extended temperature range -20 °C to 0, 40 °C to 50 °C (NH
3
and ClO
2
only: -20 °C to 0 °C)