CAUTION
When removing the back of the case, be careful not to pull
the buzzer wire from the connector. This is a fragile connector;
use minimum force necessary to prevent breakage; breakage
of this wire is not covered under warranty. If removing the
connector, place a flat screwdriver at the back of the connector
and gently pry connector loose.
7. Remove the buzzer connector.
8. Disconnect the white ribbon connector from the main board
socket by CAREFULLY lifting up the brown locking tabs until
they stop (FIGURE 3-2).
9. Locate the edge of the main pc board that is furthest from the
display; grasp this edge and gently lift the board straight up
and away from the unit until it is free.
10. Holding the white connector, gently rock the main pc board
and pull it away from the connector.
NOTE: Retain foam rubber gasket accompanying pc board.
11. Connect the new main pc board to the white ribbon
connector by gently rocking the pc board into place; latch
down the two tabs located on either side of the ribbon socket.
12. Replace gasket and insert the new main pc board into
position; gently press down until the board snaps into place.
13. Reconnect the buzzer wire.
14. Replace the main pc board, ensuring gasket is appropriately
placed around the entire perimeter of the instrument.
"
CAUTION
When replacing the back of the case, tuck the buzzer wire
between the display board and the main board to prevent
damage to the wire.
15. Replace back of
the case and
tighten the six
case-mounting
screws securing
the back of
the case in the
Figure 3-2.
Display Connector