MSA FiveStar Instruction Manual Page 61

  • Download
  • Add to my manuals
  • Print
  • Page
    / 71
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 60
Nitrogen Dioxide Sensor Specifications
Table 4-11. NITROGEN DIOXIDE (appropriate models only) -
Typical Performance Specifications
RANGE
100 ppm
RESOLUTION
0.5 ppm
REPRODUCIBILITY
+2 ppm or +10% of reading, whichever is greater
RESPONSE TIME
50 seconds*
*See TABLE 4-1, NOTE 1.
Table 4-12. NITROGEN DIOXIDE - Cross Reference Factors for
FiveStar Calibration Using Calibration Cylinder (P/N 808977)
Set to 10 ppm NO
2
NOTE: Data is presented as the indicated output in ppm,
which would result from the application of 100 ppm of the test gas.
TEST GAS EQUIVALENT PPM
Carbon Monoxide (CO)
< -5
Hydrogen Sulfide (H
2
S)
-8 +2
Nitric Oxide (NO)
0
Sulfur Dioxide (SO
2
)
0
Chlorine (Cl
2
)
-100 +15
Ammonia (NH
3
)
0
Carbon Dioxide (CO
2
)
0
Chlorine Dioxide (ClO
2
)
150 (over)
Chapter 4, Performance Specifications Instruction Manual